The IE3 electric motor is in line with the third efficiency standard in the provisions of GB 18613-2012"the energy efficiency limit and the energy efficiency rating of small and medium-size three-phase asynchronous motors ".And the improvement of the efficiency in its design is in line with the state's requirements for energy saving and consumption reducing of the manufacturing sector.
|
Type No. IE3 |
|
|
|
|
|
% |
|
N.m |
|
|
|
|
|
|||||
|
|
|
IFL 380V A |
IFL 400V A |
IFL 420V A |
IFL 440V A |
IFL 460V A |
IFL 480V A |
|
|
|
||||||||
|
380 - 420V/50Hz |
440 - 480V/60Hz |
|||||||||||||||||
|
Synchronous speed 1500r/min |
||||||||||||||||||
|
IE3-80M2-4 |
0.75 |
1.0 |
1.80 |
1.71 |
1.63 |
1430 |
1.55 |
1.49 |
1.43 |
1715 |
82.5 |
0.75 |
5.01 |
2.30 |
6.60 |
2.30 |
56 |
20 |
|
IE3-90S-4 |
1.1 |
1.5 |
2.60 |
2.47 |
2.35 |
1430 |
2.25 |
2.15 |
2.06 |
1715 |
84.1 |
0.76 |
7.35 |
2.30 |
6.80 |
2.30 |
59 |
23 |
|
IE3-90L-4 |
1.5 |
2.0 |
3.50 |
3.33 |
3.17 |
1430 |
3.02 |
2.89 |
2.77 |
1715 |
85.3 |
0.77 |
10 |
2.30 |
7.00 |
2.30 |
59 |
26 |
|
IE3-100L1-4 |
2.2 |
3.0 |
4.80 |
4.56 |
4.34 |
1440 |
4.15 |
3.97 |
3.80 |
1725 |
86.7 |
0.81 |
14.6 |
2.30 |
7.60 |
2.30 |
64 |
37 |
|
E3-100L2-4 |
3 |
4.0 |
6.30 |
5.99 |
5.70 |
1440 |
5.44 |
5.20 |
4.99 |
1725 |
87.7 |
0.82 |
19.9 |
2.30 |
7.60 |
2.30 |
64 |
42 |
|
IE3-112M-4 |
4 |
5.5 |
8.40 |
7.98 |
7.60 |
1455 |
7.25 |
6.94 |
6.65 |
1745 |
88.6 |
0.82 |
26.3 |
2.20 |
7.80 |
2.30 |
65 |
49 |
|
IE3-132S-4 |
5.5 |
7.5 |
11.2 |
10.6 |
10.1 |
1465 |
9.67 |
9.25 |
8.87 |
1755 |
89.6 |
0.83 |
35.9 |
2.00 |
7.90 |
2.30 |
71 |
70 |
|
E3-132M-4 |
7.5 |
10.0 |
15.0 |
14.3 |
13.6 |
1465 |
13.0 |
12.4 |
11.9 |
1755 |
90.4 |
0.84 |
48.9 |
2.00 |
7.50 |
2.30 |
71 |
84 |
|
IE3-160M-4 |
11 |
15 |
21.5 |
20.4 |
19.5 |
1470 |
18.6 |
17.8 |
17.0 |
1760 |
91.4 |
0.85 |
71.5 |
2.00 |
7.70 |
2.30 |
73 |
130 |
|
E3-160L-4 |
15 |
20 |
28.8 |
27.4 |
26.1 |
1470 |
24.9 |
23.8 |
22.8 |
1760 |
92.1 |
0.86 |
97.4 |
2.00 |
7.80 |
2.30 |
73 |
148 |
|
E3-180M-4 |
18.5 |
25 |
35.3 |
33.5 |
31.9 |
1470 |
30.5 |
29.2 |
28.0 |
1760 |
92.6 |
0.86 |
120 |
2.00 |
7.80 |
2.30 |
76 |
192 |
|
IE3-180L-4 |
22 |
30 |
41.8 |
39.7 |
37.8 |
1470 |
36.1 |
34.5 |
33.1 |
1760 |
93.0 |
0.86 |
143 |
2.00 |
7.80 |
2.30 |
76 |
206 |
|
E3-200L-4 |
30 |
40 |
56.6 |
53.8 |
51.2 |
1475 |
48.9 |
46.8 |
44.8 |
1770 |
93.6 |
0.86 |
194 |
2.00 |
7.30 |
2.30 |
76 |
275 |
1. Stoppage: No-load motor can't start
1. Circuit broken wires (one of the three is the root)
2. When the child three-phase winding of the a phase breakers ( "Y" type of connection)
3. The power supply voltage and frequency are wrong
1. Check the power supply voltage or individual connection.
2. Check the fuse, feeders of current and each phase of the winding resistance.
3. Check voltage and frequency
2. Stoppage: Motor load in cannot begin at low load or no-load to start when, but in load increase speed that are even stop to plunge
1. The low-voltage power supply
2. The group turns around the son between short circuit
3. The stator three-phase winding out-of-phase break line ( "A" then method)
4. Overload
1. Check the line voltage;
2. Check each phase winding and each phase no-load current;
3. Check each phase winding resistance;
4. Check the load
étiquette à chaud: ie3 electric motor, China ie3 electric motor manufacturers, factory